Hypro D70 and D70 GR

Low Pressure Pump

Features

  • Max. flow: 19 gpm/71.8 L/min

  • Max. pressure: 290 psi/20 BAR

  • Max. rated speed: 550 rpm

  • Max. fluid temperature: 140 degrees F

  • Port sizes: 1 1/4" inlet, 3/4" outlet, hose barb

  • Diaphragms: 2, semi-hydraulic

  • Housing components for liquid handling: epoxy-coated

  • Weight: 25 lbs.

  • Pump shaft rotation: CW and CCW

      Recommended control unit: 3300-0087 or 3300-0088

 

Hypro D70 Pump

All HP requirements listed in the table below are electrical. For approximate gasoline equivalent multiply by 1.3

Pressure in PSI and BAR GPM HP GPM HP GPM HP GPM HP GPM HP
L/min W L/min W L/min W L/min W L/min W
@350 RPM @400 RPM @450 RPM @500 RPM @550 RPM
0 PSI 12.7 0.3 13.7 0.3 15.7 0.4 17.2 0.6 19.0 0.6
0 BAR 47.9 200 51.9 200 59.6 300 65.0 400 71.8 400
145 PSI 10.7 1.2 11.0 1.4 13.5 1.6 14.9 1.8 16.0 1.9
10 BAR 40.4 900 41.6 1000 51.2 1200 56.4 1300 60.4 1400
217 PSI 10.3 1.7 10.5 2.0 13.4 2.3 14.4 2.5 15.9 2.7
15 BAR 39.0 1300 39.7 1400 50.6 1700 54.4 1900 60.1 2000
290 PSI 10.0 2.2 10.0 2.5 13.0 2.8 14.1 3.1 15.8 3.4
20 BAR 37.8 1600 37.9 1900 49.2 2100 53.2 2300 59.7 2500

 

Pump Dimensions

  Standard Metric
A 9 1/4" 247 mm
B 3" 76 mm
C 9 1/8" 232 mm
D 8 1/2" 216 mm

To Hyperlink to D70 Pricing and Parts Breakdowns Click below

Hypro D70 Pump

Return to Home

Return to Diaphragm Main

  copyright 2007
    www.rittenhouse.ca